Product Name: Myoglobin(Fluorescence Immunochromatography Assay)
Abbreviation: Myo
APPLICATION:
For the quantitative detection of myoglobin in human serum, plasma or whole blood.
Myoglobin is an oxygen-binding heme protein, and mainly distributed in myocardium and skeletal muscle tissue. In acute myocardial injury, myoglobin is first released into the blood. After about 2-3 hours of symptoms, myoglobin in the blood can exceed the upper limit of normal, peaking at 9-12 hours, and returning to normal after 24-36 hours. Determination of serum myoglobin is as the early and most sensitive indicator of acute myocardial infarction (AMI) diagnosis.
PRCINCIPLE:
Take the sample to the strip, the MYO in the sample is bound to the antibody coated with the fluorescent particles coated on the glass fiber to form a fluorescent particle-antibody-antigen complex. The immune complex is further chromatographed along the nitrocellulose membrane to the detection zone (T), and combined with the pre-coated mouse anti-MYO monoclonal antibody, the fluorescence intensity is proportional to the MYO content in the sample, and the remaining fluorescent antibody particle layer Factored to the QC zone (C) and bound to pre-coated goat anti-mouse IgG.
Method:
Fluorescence Immunoassay
Assay Time: 15 min
Sample Volume: 20µl
Sample Type: Serum / Plasma / Whole blood
Technical parameters:
Reference Range: 0-58ng/ml
Analytical Sensitivity: 5ng/ml
Measuring Range: 5 ~ 400 ng/mL
Precision: Intra-assay CV<10%, Inter-assay CV<15%.
Stability: Stable up to 18 months if stored at 2 - 30°C in its sealed pouch.
STORAGE AND STABILITY:
The strip is stable for 18months (while sealed in an aluminum foil pouch) if stored at 2 ° C - 30 ° C. After the strip is opened, the test should be performed in 1 hour. The date of manufacture is detailed in the label.
Package:
25 pieces/box
Name | Composition |
Strip | Consisting of a cartridge and a strip, the test strip comprises a sample pad, a glass fiber (coated with a fluorescent particle- Myo antibody conjugate), a nitrocellulose membrane (the detection zone is coated with a Myo monoclonal antibody, and the quality control zone is coated with a sheep) Anti-mouse IgG), absorbent paper, PVC board. |
Magcard | Have Calibration curve information of this batch reagents. |
Buffer | Main component is phosphate buffered saline (PBS). |
QC(Optional) | Freeze-dried products, the target value of each batch is shown in the target value list. |
Manual | To descripe basic information, usage methods and precautions |
Applicable POCT Analyzer
D-10, D-20, KHF01