Welcome to DIAGREAT!
Hotline: 86 010-69502385
Products Products
Product name

MPA

Release time 2018-12-08
Clicks 23

Product Name: Mycophenolic acid (Immunochromatographic Assay

Abbreviation: MPA

 

APPLICATION:

For the quantitative determination of mycophenolic acid in human serum, plasma or whole blood.

Mycophenolic acid is a commonly used immunosuppressant in organ transplantation. Free mycophenolic acid has pharmacological activity, and its metabolism is affected by many factors, resulting in individual differences in blood drug concentration. The content of enzymatic phenolic acid in human body is determined, and the dosage regimen is designed according to the individual characteristics and disease state of the patient, and provides a reference for achieving individualized administration, improving curative effect and reducing adverse reaction of the medicine clinically.

 

PRCINCIPLE:

Take the sample to the strip, The MPA in the specimen binds to an antibody coated with a fluorescent particle coated on the glass fiber to form a fluorescent particle-antibody-antigen complex. The immune complex is chromatographed along the nitrocellulose membrane to the detection zone (T), which binds to the pre-coated MPA-BSA conjugate and its fluorescence intensity is inversely proportional to the MTX content of the sample. The anti-IgY fluorescent antibody particles are chromatographed to the quality control zone (C) and bound to the pre-coated Organic IgY.

 

Method:

Time-Resolved Immunofluorescence Chromatography

Assay Time: 15 min

Sample Volume: 20µl

Sample Type: Serum / Plasma / Whole blood

 

Technical parameters:

Analytical Sensitivity: 0.1µg/mL

Measuring Range: 0.1 ~ 20 μg/mL

Precision: Intra-assay CV<10%, Inter-assay CV<15%.

Accuracy: Relative deviation of Quality control<10%

Stability: Stable up to 18 months if stored at 2 - 30°C in its sealed pouch.

 

STORAGE AND STABILITY:

The strip is stable for 18months (while sealed in an aluminum foil pouch) if stored at 2 ° C - 30 ° C, the fluorescent antibody in a tube is stable for 18months if stored at 2 ° C - 8 ° C, and the dissociation liquid in a tube is stable for 18months if stored at 2 ° C - 30 ° C. After the strip is opened, the test should be performed in 1 hour.

The date of manufacture is detailed in the label.

 

Package:

25 pieces/box

Name

Composition

Strip

Consisting of a cartridge and a strip, the test strip comprises a sample pad, a glass fiber (Coated with fluorescent particles -MPA antibody conjugate, fluorescent particle - IgY antibody conjugate), nitrocellulose membrane (detection zone coated with MPA-BSA conjugate, quality control zone coated with organic IgY), absorbent paper, PVC board.

Magcard

Have Calibration curve information of this batch reagents.

Buffer

Main component is phosphate buffered saline (PBS).

QC(Optional)

Freeze-dried products, the target value of each batch is shown in the target value list.

Manual

To descripe basic information, usage methods and precautions

 

 

Applicable POCT Analyzer

DG-1

MPA

Recommend / Products MORE+
Links:
  • Your name:
  • *
  • Your phone:
  • *
  • Your mailbox:
  • *
  • Your needs:
  • *
     
Address: three floor, new Hualian science and technology building, 5 jiaxhuang Road, Tongzhou District, Beijing.
Telephone: 86 010-69502385
Fax: 86 010-69507615
Zip code:330520
Copyright ©2018 - 2019  DIAGREAT
Rhino cloud provides enterprise cloud services
犀牛云提供云计算服务