Welcome to DIAGREAT!
Hotline: 86 010-69502385
Products Products
Product name

CTNI

Release time 2018-12-08
Clicks 23

Product Name: Troponin IImmunochromatographic Assay

Abbreviation:  cTnI

 

APPLICATION:

For the quantitative detection of troponin I in human serum, plasma or whole blood.

 

PRCINCIPLE:

Cardiac troponin I (cTnI) is a 22.5KD myocardial protein. It forms a cardiac troponin complex with troponin T (TnT) and troponin C (TnC), to complete basic function of intracellular actin of calcium signaling between interactions. It has high specificity and diagnostic sensitivity in the diagnosis of acute myocardial infarction.

 

Method:

Time-Resolved Immunofluorescence Chromatography

Assay Time: 15 min

Sample Volume: 20µl

Sample Type: Serum / Plasma / Whole blood

 

Technical parameters:

Analytical Sensitivity: ≤0.1ng/ml

Measuring Range: 0.1 ~ 40 ng/mL

Precision: CV≤15%

Stability: Stable up to 18 months if stored at 2 - 30°C in its sealed pouch.

 

STORAGE AND STABILITY:

The strip is stable for 18months (while sealed in an aluminum foil pouch) if stored at 2 ° C - 30 ° C, the fluorescent antibody in a tube is stable for 18months if stored at 2 ° C - 8 ° C, and the dissociation liquid in a tube is stable for 18months if stored at 2 ° C - 30 ° C. After the strip is opened, the test should be performed in 1 hour.

The date of manufacture is detailed in the label.

 

Package:

25 pieces/box

Name

Composition

Strip

Consisting of a cartridge and a strip, the test strip comprises a sample pad, a glass fiber (coated with a fluorescent particle- cTnI antibody conjugate), a nitrocellulose membrane (the detection zone is coated with a cTnI monoclonal antibody, and the quality control zone is coated with a sheep) Anti-mouse IgG), absorbent paper, PVC board.

Magcard

Have Calibration curve information of this batch reagents.

Buffer

Main component is phosphate buffered saline (PBS).

QC(Optional)

Freeze-dried products, the target value of each batch is shown in the target value list.

Manual

To descripe basic information, usage methods and precautions

 

 

Applicable POCT Analyzer

DG-1


Recommend / Products MORE+